Products Your location:Home > Air-cooled screw chillers
Air-cooled screw chillers
Product Description
Compressor features>>
◆ the use of international brand compressor, the new sub-efficient rotary screw compressors, compressor performance than the average 20% -30% higher, and European and American multi-national patent quality certification of the IS9001.
◆ High efficiency patented 5:6 asymmetric rotor profile.
◆-style volume control can be four (100% -75% -50% -25%) or three-(100-66% -33%) and Stepless control system.
◆ the use of bearings 11 and a type of axial thrust balance portfolio design, bearing life increased 2.5-3.5 times.
◆ special high-efficiency silicon steel sheet corrugated design, and equipped with omni-directional design both inside and outside the cooling flow to the compressor motor at any load can be played under the maximum efficiency.
◆ unique built-in hydraulic system, there is no need also to ensure that the compressor oil pump to maintain the best lubricating effect of oil separation of double-filtering method The oil filter good results, can play a maximum capacity of heat exchangers.
◆ High efficiency, low noise, low vibration.
◆ to choose from a variety of refrigerants, with the exception of R22 refrigerant, but also can choose to use R134a, R407c refrigerant, such as environmental protection.
◆ a full range of compressor capacity (VI = 2.2/2.6/3.0/3.5) options, which can effectively avoid the compressor or compressors have been caused by less than the additional energy consumption.
Air-cooled screw chillers (single head) parameters
|
Project / Model |
DX-100AS |
DX-130AS |
DX-150AS |
DX-210AS |
DX-240AS |
DX-260AS | |
|
Cooling capacity |
Btu/h |
341200 |
443560 |
511800 |
716520 |
818880 |
887120 |
|
Kcal/h |
86000 |
111800 |
129000 |
180600 |
206400 |
223600 | |
|
Kw |
100 |
130 |
150 |
210 |
240 |
260 | |
|
Enter the total power |
KW |
39 |
43 |
49 |
67 |
73 |
84 |
|
Maximum operating current |
A |
91 |
116 |
122 |
165 |
215 |
250 |
|
Power Supply |
3PH-380V-50HZ | ||||||
|
Refrigerants |
R22/R407C | ||||||
|
Refrigeration circuit |
1 | ||||||
|
Refrigerant flow control mode |
Outside the balance temperature thermal expansion valve | ||||||
|
Compressor |
Type |
Semi-hermetic screw | |||||
|
Amount |
1 | ||||||
|
Start-up mode |
Y-△Start | ||||||
|
Energy Control(%) |
0-25-50-75-100 | ||||||
|
Condenser |
Type |
With air-cooled screw-type high-performance aluminum brass sets | |||||
|
Power(KW) |
3.9 |
4.3 |
5.5 |
7.5 |
8.8 |
8.8 | |
|
Air volume(m3/h) |
40000 |
48000 |
60000 |
75000 |
100000 |
100000 | |
|
Evaporator |
Type |
Dry-type shell and tube | |||||
|
Amount |
1 | ||||||
|
Chilled water flow (m3/h) |
17 |
22 |
26 |
36 |
41 |
45 | |
|
Access to water pipes by |
3 |
3 |
3 |
3 |
4 |
4 | |
|
Safety protection device |
Compressor over-temperature protection, overload protection device units, high and low pressure protection device, antifreeze protection devices, power reverse / lack of protection, and traffic protection. | ||||||
|
Unit weight |
Kg |
1600 |
1800 |
1950 |
2260 |
2500 |
2800 |
|
Operation weight |
Kg |
1800 |
2000 |
2150 |
2420 |
2800 |
3100 |
|
Project / Model |
DX-320AS |
DX-400AS |
DX-460AS |
DX-500AS |
DX-570AS |
DX-620AS | |
|
Cooling capacity |
Btu/h |
1091840 |
1365600 |
1569520 |
1706000 |
1944840 |
2115440 |
|
Kcal/h |
275200 |
344000 |
395600 |
430000 |
490200 |
533200 | |
|
Kw |
320 |
400 |
460 |
500 |
570 |
620 | |
|
Enter the total power |
KW |
103 |
120 |
143 |
158 |
183 |
201 |
|
Maximum operating current |
A |
275 |
290 |
352 |
395 |
454 |
493 |
|
Power Supply |
3PH-380V-50HZ | ||||||
|
Refrigerants |
R22/R407C | ||||||
|
Refrigeration circuit |
1 | ||||||
|
Refrigerant flow control mode |
Outside the balance temperature thermal expansion valve | ||||||
|
Compressor |
Type |
Semi-hermetic screw | |||||
|
Amount |
1 | ||||||
|
Start-up mode |
Y-△Start | ||||||
|
Energy Control(%) |
0-25-50-75-100 | ||||||
|
Condenser |
Type |
With air-cooled screw-type high-performance aluminum brass sets | |||||
|
Power(KW) |
12 |
12 |
13.2 |
15 |
18 |
21 | |
|
Air volume(m3/h) |
140000 |
140000 |
164000 |
180000 |
210000 |
235000 | |
|
Evaporator |
Type |
Dry-type shell and tube | |||||
|
Amount |
1 | ||||||
|
Chilled water flow (m3/h) |
55 |
67 |
79 |
86 |
98 |
107 | |
|
Access to water pipes by |
4 |
5 |
5 |
6 |
6 |
6 | |
|
Safety protection device |
Compressor over-temperature protection, overload protection device units, high and low pressure protection device, antifreeze protection devices, power reverse / lack of protection, and traffic protection. | ||||||
|
Unit weight |
Kg |
3500 |
3800 |
4200 |
4500 |
4800 |
5300 |
|
Operation weight |
Kg |
3800 |
4200 |
4600 |
4900 |
5300 |
5800 |
Air-cooled screw chillers (double nose) parameters
|
Project / Model |
DX-210AD |
DX-260AD |
DX-320AD |
DX-400AD |
DX-470AD |
DX-510AD |
DX-640AD | |
|
Cooling capacity |
Btu/h |
716520 |
887120 |
1057720 |
1364800 |
1586580 |
1736708 |
2183680 |
|
Kcal/h |
180600 |
223600 |
266600 |
344000 |
399900 |
437740 |
550400 | |
|
Kw |
210 |
260 |
310 |
400 |
465 |
509 |
640 | |
|
Enter the total power |
KW |
72 |
86 |
99 |
134 |
146 |
168 |
205 |
|
Maximum operating current |
A |
182 |
232 |
244 |
330 |
430 |
500 |
550 |
|
Power Supply |
3PH-380V-50HZ | |||||||
|
Refrigerants |
R22/R407C | |||||||
|
Refrigeration circuit |
1 | |||||||
|
Refrigerant flow control mode |
Outside the balance temperature thermal expansion valve | |||||||
|
Compressor |
Type |
Semi-hermetic screw | ||||||
|
Amount |
1 | |||||||
|
Start-up mode |
Y-△Start | |||||||
|
Energy Control(%) |
0-25-50-75-100 | |||||||
|
Condenser |
Type |
With air-cooled screw-type high-performance aluminum brass sets | ||||||
|
Power(KW) |
7.5 |
8.8 |
12 |
12 |
13.2 |
15 |
21 | |
|
Air volume(m3/h) |
75000 |
100000 |
140000 |
140000 |
164000 |
180000 |
235000 | |
|
Evaporator |
Type |
Dry-type shell and tube | ||||||
|
Amount |
1 | |||||||
|
Chilled water flow(m3/h) |
36 |
45 |
53 |
69 |
80 |
88 |
110 | |
|
Access to water pipes by |
3 |
4 |
4 |
5 |
5 |
6 |
6 | |
|
Safety protection device |
Compressor over-temperature protection, overload protection device units, high and low pressure protection device, antifreeze protection devices, power reverse / lack of protection, and traffic protection. | |||||||
|
Unit weight |
Kg |
2400 |
2700 |
3700 |
4000 |
4400 |
4800 |
5500 |
|
Operation weight |
Kg |
2700 |
2950 |
4000 |
4350 |
4800 |
5200 |
5950 |